COMO PONCHAR UN CABLE UTP PDF

PASOS PARA PONCHAR. UN CABLE UTP MATERIALES. 1 COMO MINIMO 1 METRO DE CABLE UTP. 2 PONCHADORA. 3 UN PAR DE RJ Ponchado de Un Cable Utp Categoria 5 – Free download as Word Doc .doc /. docx), PDF File .pdf), Text File como ponchar un cable utp cat5 paso a paso.

Author: Bakasa Kajora
Country: Benin
Language: English (Spanish)
Genre: Technology
Published (Last): 27 June 2007
Pages: 165
PDF File Size: 8.18 Mb
ePub File Size: 1.91 Mb
ISBN: 741-7-55516-404-6
Downloads: 11571
Price: Free* [*Free Regsitration Required]
Uploader: Kigakinos

Is there a way I can import all my wordpress posts into it? If you are planning tu use a hub or switch, both ends cablee the cable the one connected to the host and the one connected to the network concentrator must been built following the same standard. I merely wanted to give you a quick heads up! Any help would be greatly appreciated! The other end A.

Pair 1 connected pins 4 and 5. I definitely enjoyed every bit of it and I have you book marked to see new information on your site. Remember to choose one standard and stick to it. This has been an incredibly wonderful post. To find out if the cable you are planning to use is the wright one, you must search over the calbe serigraphy factory prints for something like shown in the image below: Pair 3 connected opnchar pins 1 and 2: When I look at your site in Safari, it looks fine but when opening in I.

En Colombia generalmente se le dice “Ponchado” en Argentina: So you will find 4 twisted pairs of 2 twisted wires.

The difference between UTP and STP is an extra shield, metal or teflon, placed under the PVC protection, envolving the wires for better magnetic and electrostatic isolation. Por gabovanlugo el 13 de Septiembre de As I explained before, each cabld has a colour wire and a white wire with a dash line of the same colour.

  DEVASSOS POR NATUREZA PDF

Cab,e wanted to thank you for your time for this wonderful read!! Asegurese que todas las puntas lleguen hasta el tope del canal dentro del conector.

I was very pleased to uncover this site. Envia un comentario Nesecito conectar una punta de el cable en un jack. Disculpen una pregunta que pasa si de mi cable de red ponchxr rompe uno deloa cablesitoa es posible que si aya ntertnet? Thank you and best of luck. Por tosslove el 13 de Septiembre de Descubriendo que hay detras de cada puerto. Si tus dudas son acerca de cableado Cat. The colour code and pairs order are the same.

Guía para Cableado de Redes – La disyuntiva del Perro

Publica tu comentario Tu nombre: I care for such info a lot. Pair 2 connected to pin 1 and 2: La siguiente tabla muestra el orden normal de los pares de cables, no su forma de conectarse: Los pares juntados y nivelados deben verse asi: This connectors are made of a sort of transparent acrylic, where the cable with all pairs in the proper order is inserted and then secured using a crimping tool.

Por tosslove el 30 de Septiembre de Pelotudo debes yn cable cruzado solo si vas conectar de pc a pc, para pc a switch es cable directo. Very useful info particularly the last part: Is there anybody else having similar RSS issues? If you ar searching for Gigabit lan or speed and cble over networks, I strongly recommend you to read my post entitled Gigabit ethernet after you finish with this one.

Punta 1 y 2 B. Para switch o hub, no deben de ser la misma norma por ambos lados del cables? I was ut; this particular information for a very long time. En la imagen estoy ponchando un cable con norma B por un lado: Par 2 conectado a pin 1 y 2: Utpp conector es una pieza de plastico transparente en donde se inserta el cable.

  CAPPELLI.DIZIONARIO DI ABBREVIATURE PDF

Si quiere conectar su PC al modem le interesa hacer un cable cruzado norma A de un lado y norma B del otro lado. I know, pro themes are expensive, but there is solution for this.

Guía para Cableado de Redes

The other two pairs should be connected as follows for both standards: Por Mariux el 30 de Septiembre de Putting pairs in the correct order The colour pairs are numbered from 1 to 4, but this has nothing to do with the wire order for standards! Both ends based on standard B. The following image shows the UTP pairs in order, not the way they should be connected: Is anyone else having this problem or is it a issue on my end? En la parte que dice “Si quiere conectar su PC a un switch, enrutador, hub, probablemente prefiera un cable cruzado, lo cual indica una norma de un lado y otra norma del otro lado.

Anyone who knows the answer can you kindly respond? Es decir si ponchamos la norma A en un lado, tambien debo ponchar la norma A en el otro extremo. Es importante que comprendan que al momento de armar su red, deben optar por uno de estas normas A o B y mantenerla para todos los cables del tendido.

Author: admin